  Datasheet File OCR Text:
  mechanical information: fixture weight: see ordering info below mounting: accommodates a 2 ip (2.375 od) pipe. provision for adjustment of +/- 5 in 2.5 increments electrical specifications: operating voltage: 100-277v ac total system power consumption: see ordering info below led drive current: 348ma operating temp: -40f to 165f (-40c to 74c) noise requirements / fcc title 47, subpart b, section 15, class a emc: device. rf immunity; 10v/m, 80mhz-1ghz transient protection: ansi c136.2 (600v classification) dielectric and transient voltage withstand tests thd: <15% (100 - 240v ac) <20% (277v ac) power factor: >0.95 material: housing: cast aluminum housing with terminal block for up to 6awg wire. unique hinged grey polycarbonate bottom cover provides tool less access to terminal blocks and pole fittings for quick and easy luminaire mounting. finish: polyester / epoxy powder coat grey. standard ral 7040. (other finish options available on request.) lens: uv and abrasion resistant polycarbonate cover lens (glass lens options available on request.) photocontroller socket: standard nema three prong twist lock, socket with shorting cap, as per ansi c136.10 photometric information: cri (typ): 72 (cool white) 75 (neutral white) cct (typ): 6,000k (cool white) 4,300k (neutral white) optics: ies type iii (types ii, iv, v available on request) certifications and ratings: ? ul1598 ? csa c22.2 #250 ? ip 66 ? ida dark sky compliances: ? rp-8-00 test reports: ? lm-79 ? lm-80 features & benefits: ? instant on/off response ? environment friendly ? resistant to shock and vibration ? 70% lumen maintenance over 80,000 operating hours ? built-in thermal overload protection circuitry ? built-in surge protection circuitry accessories (ordered separately): ? photo controller - part number - slpc01r www.dialight.com a new direction in roadway lighting representing the latest innovation in led roadway and area lighting, the new dialight streetsense? series led street light features dialights exclusive optics technology for precision light placement along with maximum energy efficiency and reliability for ultra-low total cost of ownership over the lifetime of the fixture. part number total system power consumption (w) cct (typ) initial fixture lumens lumen per watt bug rating fixture weight (lbs) epa (sq. ft) dimensions (inches) sl3c4clgh 61 6,000k 4,466 73 b1u2g1 16 0.60 18.4 x 14.7 x 4.8 SL3C4HLGH 121 6,000k 8,985 74 b2u3g2 25 0.87 26.5 x 14.7 x 4.8 sl3c4rlgh 182 6,000k 13,471 74 b3u3g3 34 1.13 34.7 x 14.7 x 4.8 *sl3n4clgh 61 4,300k 4,214 69 b1u2g1 16 0.60 18.4 x 14.7 x 4.8 *sl3n4hlgh 121 4,300k 8,428 70 b2u3g2 25 0.87 26.5 x 14.7 x 4.8 *sl3n4rlgh 182 4,300k 12,615 69 b3u3g3 34 1.13 34.7 x 14.7 x 4.8 streetsense ? series led street light 34.7 (880) 26.5 (674) 18.4 (467) 4.8 (122) 14.7 (372) dimensions in inches (mm) *lumen values for neutral white part numbers based on preliminary ies files. lm-79 pending. patent pending
type iii (61 watt cool white) - light measurement data lm-79 certified iso-illuminance chart (fc) intensity distribution curve (cd) example shown: 25 ft mounting height spacing of each box is equal to mounting height in feet. ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft iso-illuminance chart (fc) intensity distribution curve (cd) example shown: 35 ft mounting height type iii (121 watt cool white) - light measurement data lm-79 certified www.dialight.com iso-illuminance chart (fc) intensity distribution curve (cd) example shown: 35 ft mounting height type iii (182 watt cool white) - light measurement data lm-79 certified - location of streetlight mounting height multiplier 10 6.250 15 2.778 20 1.563 25 1.000 30 0.694 35 0.510 40 0.319 45 0.309 50 0.250 mounting height multiplier 10 12.250 15 5.444 20 3.063 25 1.960 30 1.361 35 1.000 40 0.766 45 0.605 50 0.490 mounting height multiplier 10 12.250 15 5.444 20 3.063 25 1.960 30 1.361 35 1.000 40 0.766 45 0.605 50 0.490 0.01 0.02 0.05 0.1 0.2 0.5 1. etl intertek certified test performed to ies lm-79-08 standards etl intertek certified test performed to ies lm-79-08 standards etl intertek certified test performed to ies lm-79-08 standards 0.01 0.02 0.05 0.1 0.2 0.5 1. 0.01 0.02 0.05 0.1 0.2 0.5 2. spacing of each box is equal to mounting height in feet. ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft - location of streetlight spacing of each box is equal to mounting height in feet. ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft - location of streetlight
type iii (61 watt neutral white) - light measurement data preliminary measurements iso-illuminance chart (fc) intensity distribution curve (cd) example shown: 25 ft mounting height spacing of each box is equal to mounting height in feet. ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft iso-illuminance chart (fc) intensity distribution curve (cd) example shown: 35 ft mounting height dialight reserves the right to make changes at any time in order to supply the best product possible. the most current version of this document will always be available at: www.dialight.com/assets/brochures_and_catalogs/illumination/mdtfsl3x001.pdf iso-illuminance chart (fc) intensity distribution curve (cd) example shown: 35 ft mounting height type iii (182 watt neutral white) - light measurement data preliminary measurements - location of streetlight mounting height multiplier 10 6.250 15 2.778 20 1.563 25 1.000 30 0.694 35 0.510 40 0.319 45 0.309 50 0.250 mounting height multiplier 10 12.250 15 5.444 20 3.063 25 1.960 30 1.361 35 1.000 40 0.766 45 0.605 50 0.490 mounting height multiplier 10 12.250 15 5.444 20 3.063 25 1.960 30 1.361 35 1.000 40 0.766 45 0.605 50 0.490 0.01 0.02 0.05 0.1 0.2 0.5 1. 0.01 0.02 0.05 0.1 0.2 0.5 1. 0.01 0.02 0.05 0.1 0.2 0.5 2. spacing of each box is equal to mounting height in feet. ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft - location of streetlight spacing of each box is equal to mounting height in feet. ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft - location of streetlight 1. mdtfsl3x001_b type iii (121 watt neutral white) - light measurement data preliminary measurements


▲Up To Search▲   

 
Price & Availability of SL3C4HLGH

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X